6.1. Introduction¶
LIRC stands for Linux Infrared Remote Control. The LIRC device interface is a bi-directional interface for transporting raw IR and decoded scancodes data between userspace and kernelspace. Fundamentally, it is just a chardev (/dev/lircX, for X = 0, 1, 2, ...), with a number of standard struct file_operations defined on it. With respect to transporting raw IR and decoded scancodes to and fro, the essential fops are read, write and ioctl.
It is also possible to attach a BPF program to a LIRC device for decoding raw IR into scancodes.
Example dmesg output upon a driver registering w/LIRC:
$ dmesg |grep lirc_dev
rc rc0: lirc_dev: driver mceusb registered at minor = 0, raw IR receiver, raw IR transmitter
What you should see for a chardev:
$ ls -l /dev/lirc*
crw-rw---- 1 root root 248, 0 Jul 2 22:20 /dev/lirc0
Note that the package v4l-utils contains tools for working with LIRC devices:
- ir-ctl: can receive raw IR and transmit IR, as well as query LIRC device features.
- ir-keytable: can load keymaps; allows you to set IR kernel protocols; load BPF IR decoders and test IR decoding. Some BPF IR decoders are also provided.
6.2. LIRC modes¶
LIRC supports some modes of receiving and sending IR codes, as shown on the following table.
LIRC_MODE_SCANCODE
This mode is for both sending and receiving IR.
For transmitting (aka sending), create a
struct lirc_scancode
with the desired scancode set in thescancode
member,rc_proto
set to the IR protocol, and all other members set to 0. Write this struct to the lirc device.For receiving, you read
struct lirc_scancode
from the LIRC device. Thescancode
field is set to the received scancode and the IR protocol is set inrc_proto
. If the scancode maps to a valid key code, this is set in thekeycode
field, else it is set toKEY_RESERVED
.The
flags
can haveLIRC_SCANCODE_FLAG_TOGGLE
set if the toggle bit is set in protocols that support it (e.g. rc-5 and rc-6), orLIRC_SCANCODE_FLAG_REPEAT
for when a repeat is received for protocols that support it (e.g. nec).In the Sanyo and NEC protocol, if you hold a button on remote, rather than repeating the entire scancode, the remote sends a shorter message with no scancode, which just means button is held, a "repeat". When this is received, the
LIRC_SCANCODE_FLAG_REPEAT
is set and the scancode and keycode is repeated.With nec, there is no way to distinguish "button hold" from "repeatedly pressing the same button". The rc-5 and rc-6 protocols have a toggle bit. When a button is released and pressed again, the toggle bit is inverted. If the toggle bit is set, the
LIRC_SCANCODE_FLAG_TOGGLE
is set.The
timestamp
field is filled with the time nanoseconds (inCLOCK_MONOTONIC
) when the scancode was decoded.
LIRC_MODE_MODE2
The driver returns a sequence of pulse and space codes to userspace, as a series of u32 values.
This mode is used only for IR receive.
The upper 8 bits determine the packet type, and the lower 24 bits the payload. Use
LIRC_VALUE()
macro to get the payload, and the macroLIRC_MODE2()
will give you the type, which is one of:
LIRC_MODE2_PULSE
Signifies the presence of IR in microseconds.
LIRC_MODE2_SPACE
Signifies absence of IR in microseconds.
LIRC_MODE2_FREQUENCY
If measurement of the carrier frequency was enabled with ioctl LIRC_SET_MEASURE_CARRIER_MODE then this packet gives you the carrier frequency in Hertz.
LIRC_MODE2_TIMEOUT
If timeout reports are enabled with ioctl LIRC_SET_REC_TIMEOUT_REPORTS, when the timeout set with ioctl LIRC_GET_REC_TIMEOUT and LIRC_SET_REC_TIMEOUT expires due to no IR being detected, this packet will be sent, with the number of microseconds with no IR.
LIRC_MODE_PULSE
In pulse mode, a sequence of pulse/space integer values are written to the lirc device using LIRC write().
The values are alternating pulse and space lengths, in microseconds. The first and last entry must be a pulse, so there must be an odd number of entries.
This mode is used only for IR send.
6.3. BPF based IR decoder¶
The kernel has support for decoding the most common IR protocols, but there are many protocols which are not supported. To support these, it is possible to load an BPF program which does the decoding. This can only be done on LIRC devices which support reading raw IR.
First, using the bpf(2) syscall with the BPF_LOAD_PROG
argument,
program must be loaded of type BPF_PROG_TYPE_LIRC_MODE2
. Once attached
to the LIRC device, this program will be called for each pulse, space or
timeout event on the LIRC device. The context for the BPF program is a
pointer to a unsigned int, which is a LIRC_MODE_MODE2
value. When the program has decoded the scancode, it can be submitted using
the BPF functions bpf_rc_keydown()
or bpf_rc_repeat()
. Mouse or pointer
movements can be reported using bpf_rc_pointer_rel()
.
Once you have the file descriptor for the BPF_PROG_TYPE_LIRC_MODE2
BPF
program, it can be attached to the LIRC device using the bpf(2) syscall.
The target must be the file descriptor for the LIRC device, and the
attach type must be BPF_LIRC_MODE2
. No more than 64 BPF programs can be
attached to a single LIRC device at a time.